Section 4.8 – Texas Instruments TMS320TCI6486 User Manual
Page 83

www.ti.com
MDIO Registers
4.8
MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW)
The MDIO user command complete interrupt (unmasked) register (USERINTRAW) is shown in
and described in
Figure 35. MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW)
31
16
Reserved
R-0
15
2
1
0
Reserved
USERINTRAW
R-0
R/WC-0
LEGEND: R = Read only; R/WC = Read/Write 1 to clear; -n = value after reset
Table 28. MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW) Field
Descriptions
Bit
Field
Value
Description
31-2
Reserved
0
Reserved
1-0
USERINTRAW
MDIO User command complete event bits. When asserted, a bit indicates that the previously
scheduled PHY read or write command using that particular USERACCESS register has
completed. Writing a 1 will clear the event and writing 0 has no effect.
83
SPRUEF8F – March 2006 – Revised November 2010
C6472/TCI6486 EMAC/MDIO
Copyright © 2006–2010, Texas Instruments Incorporated