5.32 FIFO Control Register (FIFOCONTROL)

The FIFO control register (FIFOCONTROL) is shown in

Figure 74

and described in

Table 68

.

Figure 74. FIFO Control Register (FIFOCONTROL)

31

23

22

16

Reserved

RXFIFOFLOWTHRESH

R-0

R/W-2

15

5

4

0

Reserved

TXCELLTHRESH

R-0

R/W-24

LEGEND: R/W = Read/Write; R = Read only; -n = value after reset

Table 68. FIFO Control Register (FIFOCONTROL) Field Descriptions

Bit

Field

Value

Description

31-23

Reserved

0

Reserved

22-16

RXFIFOFLOWTHRESH

Receive FIFO flow control threshold. Occupancy of the receive FIFO when Receive FIFO
flow control is triggered (if enabled). The default value is 0x2, which means that receive
FIFO flow control is triggered when the occupancy of the FIFO reaches two cells.

15-5

Reserved

0

Reserved

4-0

TXCELLTHRESH

Transmit FIFO cell threshold. Indicates the number of 64-byte packet cells required to be
in the transmit FIFO before the packet transfer is initiated. Packets with fewer cells are
initiated when the complete packet is contained in the FIFO. This value must be greater
then or equal to 2 and less than or equal to 24.

130

C6472/TCI6486 EMAC/MDIO

SPRUEF8F – March 2006 – Revised November 2010

Submit Documentation Feedback