beautypg.com

Toshiba XLTR-200 User Manual

Page 81

background image

80

Parameter

Function / Title Bank

Mask

Adjustment Range

Multiplier

0133

STALL PROTECTION

ENABLE

0 / 1

0040

0000: ON

(0)

0040: OFF

(1)

0134

0

STALL

PROTECTION

CURRENT LEVEL

0 / 1

00FF

000A

∼ 00D7 (10 ∼ 215)

1

0135

UNDERVOLTAGE TRIP

SELECTION

0 / 1

0080

0000: Trip disabled

(0)

0080: Trip (during run)

(1)

0136

UNDERVOLTAGE DETECT

TIME

0 / 1

FFFF

0000

∼ 03E8 (0.00 ∼ 10.00)

0.01

0137

LOW CURRENT DETECT

SELECTION

0 / 1

0008

0000: Trip disabled

(0)

0008: Trip on detection

(1)

0138

LOW CURRENT DETECT

LEVEL

0 / 1

00FF

0000

∼ 0064 (0 ∼ 100)

1

0139

LOW CURRENT

DETECTION TIME

0 / 1

00FF

0000

∼ 00FF (0 ∼ 255)

1

0140

OUTPUT SHORT-

CIRCUIT DETECTION

SELECT

0 / 1

0003

0000: Standard motor

(0)

0001: High-speed

motor

(1)

0002: Positioning use (standard

motor) (2)

0003: Positioning use (high-speed

motor) (3)

0141

OVERTORQUE TRIP

SELECTION

0 / 1

0040

0000: Trip disabled

(0)

0040: Trip enabled

(1)

0142

OVERTORQUE TRIP

LEVEL

0 / 1

00FF

0000

∼ 00C8 (0 ∼ 200)

1

0143

FAULT TRIP EEPROM

SAVE ENABLE

0 / 1

0002

0000: Data cleared when powered

OFF (0)

0002: Data retained when powered

OFF (1)

0144

COOLING FAN CONTROL

SELECTION

0 / 1

0004

0000: Automatic (temperature

detection) (0)

0004: Always

ON

(1)

0145

CUMULATIVE RUN

TIMER ALARM SETTING

0 / 1

FFFF

0000

∼ C34B (0.00 ∼ 999.90)

0.02