8 frequency setting parameters – Toshiba XLTR-200 User Manual
Page 77
76
13.7.8 Frequency Setting Parameters
Parameter
Function / Title Bank
Mask Adjustment Range
Multiplier
0081
FREQUENCY PRIORITY
SELECTION #1
0 / 1
0007
0001: RR
(1)
0002: IV
(2)
0003: RX
(3)
0004: PG
(4)
0005: BIN
(5)
0082
FREQUENCY PRIORITY
SELECTION #2
0 / 1
0038
0008: RR
(1)
0010: IV
(2)
0018: RX
(3)
0020: PG
(4)
0028: BIN
(5)
0083
ANALOG INPUT FILTER
0 / 1
0003
0000: No filter
(0)
0001: Small filter
(1)
0002: Medium filter
(2)
0003: Large filter
(3)
0084
RR TERMINAL STANDARD
OR ADJUSTABLE
0 / 1
0002
0000: Standard
(0)
0002: Adjustable
(1)
0085
RR REFERENCE
SETTING POINT #1
0 / 1
00FF
0000
∼ 0064 (0 ∼ 100)
1
0086
RR REF POINT #1
FREQUENCY
0 / 1
FFFF
0000
∼ Fmax
0.01
0087
RR REFERENCE
SETTING POINT #2
0 / 1
00FF
0000
∼ 0064 (0 ∼ 100)
1
0088
1
RR REF POINT #2
FREQUENCY
0 / 1
FFFF
0000
∼ Fmax
0.01
0089
IV TERMINAL STANDARD
OR ADJUSTABLE
0 / 1
0004
0000: Standard
(0)
0004: Adjustable
(1)
008A
IV REFERENCE
SETTING POINT #1
0 / 1
00FF
0000
∼ 0064 (0 ∼ 100)
1
008B
IV REF POINT #1
FREQUENCY
0 / 1
FFFF
0000
∼ Fmax
0.01
008C
IV REFERENCE
SETTING POINT #2
0 / 1
00FF
0000
∼ 0064 (0 ∼ 100)
1
008D
1
IV REF POINT #2
FREQUENCY
0 / 1
FFFF
0000
∼ Fmax
0.01
008E
RX TERMINAL STANDARD
OR ADJUSTABLE
0 / 1
0008
0000: Standard
(0)
0008: Adjustable
(1)
008F
RX REFERENCE
SETTING POINT #1
0 / 1
00FF
009C
∼ 00FF, 0000 ∼ 0064
(-100
∼ -1, 0 ∼ 100)
1
0090
RX REF POINT #1
FREQUENCY
0 / 1
FFFF
-Fmax
∼ Fmax
0.02
0091
RX REFERENCE
SETTING POINT #2
0 / 1
00FF
009C
∼ 00FF, 0000 ∼ 0064
(-100
∼ -1, 0 ∼ 100)
1
0092
1
RX REF POINT #2
FREQUENCY
0 / 1
FFFF
-Fmax
∼ Fmax
0.02
0093
PG TERMINAL STANDARD
OR ADJUSTABLE
0 / 1
0010
0000: Standard
(0)
0010: Adjustable
(1)
0094
PG REFERENCE
SETTING POINT #1
0 / 1
00FF
009C
∼ 00FF, 0000 ∼ 0064
(-100
∼ -1, 0 ∼ 100)
1
0095
PG REF POINT #1
FREQUENCY
0 / 1
FFFF
-Fmax
∼ Fmax
0.02
0096
PG REFERENCE
SETTING POINT #2
0 / 1
00FF
009C
∼ 00FF, 0000 ∼ 0064
(-100
∼ -1, 0 ∼ 100)
1
0097
1
PG REF POINT #2
FREQUENCY
0 / 1
FFFF
-Fmax
∼ Fmax
0.02