Table 10: Output Terminal Selections (RCH, LOW, FL, OUT relay contacts)

Setting

Value

Data

(Hex)

Function

Setting

Value

Data

(Hex)

Function

0

0000

Lower limit frequency

32

C5B7

Executing emergency off

1

0100

/Lower limit frequency

33

CDB7

/Executing emergency off

2

0200

Upper limit frequency

34

B5BB

Executing retry

3

0300

/Upper limit frequency

35

BDBB

/Executing retry

4

0400

Low speed signal

36

D5CF

Pattern run switching output

5

0500

/Low speed signal

37

DDCF

/Pattern run switching output

6

0600

Accel/decel complete

38

D5D8

PID deviation limit

7

0700

/Accel/decel complete

39

DDD8

/PID deviation limit

8

0800

Selected speed reach signal

40

C5BB

Run/stop

9

0900

/Selected speed reach signal

41

CDBB

/Run/stop

10

0A00

Fault

42

1400

Severe fault (armature short, load-
end short, open phase, output
error, earth fault)

11

0B00

/Fault

43

1500

/Severe fault (armature short, load-
end short, open phase, output
error, earth fault)

12

0C00

Fault other than earth fault or
load-end overcurrent

44

1600

Non-severe fault (overload,
overcurrent, overvoltage)

13

0D00

/Fault other than earth fault or
load-end overcurrent

45

1700

/Non-severe fault (overload,
overcurrent, overvoltage)

14

95B5

Overcurrent pre-alarm

46

E5D8

Commercial power / inverter
switching output #1

15

9DB5

/Overcurrent pre-alarm

47

EDD8

/Commercial power / inverter
switching output #1

16

85C5

Inverter overload pre-alarm

48

F5D8

Commercial power / inverter
switching output #2

17

8DC5

/Inverter overload pre-alarm

49

FDD8

/Commercial power / inverter
switching output #2

18

95C5

Motor overload pre-alarm

50

85C0

Fan ON/OFF

19

9DC5

/Motor overload pre-alarm

51

8DC0

/Fan ON/OFF

20

D5C5

Overheat pre-alarm

52

F5B6

Executing JOG

21

DDC5

/Overheat pre-alarm

53

FDB6

/Executing JOG

22

A5B4

Overvoltage pre-alarm

54

1800

Local/remote operation

23

ADB4

/Overvoltage pre-alarm

55

1900

/Local/remote operation

24

E5B4

Undervoltage alarm

56

A5D1

Cumulative timer alarm

25

EDB4

/Undervoltage alarm

57

ADD1

/Cumulative timer alarm

26

85B5

Undercurrent alarm

58

1A00

Communication error alarm

27

8DB5

/Undercurrent alarm

59

1B00

/Communication error alarm

28 85D1

Overtorque

alarm

60 A5B6

F/R

29 8DD1

/Overtorque

alarm

61 ADB6

/F/R

30

E5BB

Braking resistor OL pre-alarm

62

1E00

Run preparation complete

31

EDBB

/Braking resistor OL pre-alarm

63

1F00

/Run preparation complete