Unusual diagnosis, Option error, Disconnection error of network cable – Toshiba Tosvert EtherNet/IP - Modbus TCP option IPE002Z User Manual
Page 80
E6581741
- 79 -
12. Unusual
diagnosis
12.1. Option error
An error message is displayed when the hardware error or software error or lose of
connection of wire is occurred.
When an option and a combination of the inverter are bad, it is displayed.
■
Display of trip information
e-23
(Error code : 55) : Optional unit fault 2
12.2. Disconnection error of network cable
When network trouble occurred by disconnection etc, the inverter does emergency stop
with the following indication when the network disconnection detection (c100, c523)
is set, and it was set in (c101=4).
■
Display of trip information
err8
(Error code: 27): Optional unit fault 1 (Communication error)