Assigning ip addresses (c504, c505-c516) – Toshiba Tosvert EtherNet/IP - Modbus TCP option IPE002Z User Manual
Page 13
E6581741
- 12 -
3.2.2.
Assigning IP addresses (c504, c505-c516)
The drive needs 3 (4-Modbus TCP) IP addresses.
*The drive IP address.
*The subnet mask.
*The gateway IP address.
(*The IP Master address.- Modbus TCP protocol only)
These parameters are effective settings at c504 = 0 (IP mode: Manual).
If the address has been given by a BOOTP or a DHCP server, these parameters are
invalidity.
• After dynamic addressing by a BOOTP or DHCP server, the new address value is
displayed in the parameters. (c524-c535)
They can be provided by:
*BOOTP server (correspondence between the MAC address and the IP addresses).
*DHCP server (correspondence between Device Name and the IP addresses).
The address is assigned according to the IP mode parameter.
c504: IP mode
Comments
0
The option uses the address defined in c505-c516.
1
The option receives its address from a BOOTP server.
2
The option receives its address from a DHCP server.
*Device name contains (c081-c096) a valid name.
Note: The IP mode parameter may be modified according to the configuration control
attribute of the TCP/IP interface object (CIP standard).