Fa23 (communication command 2) – Toshiba Tosvert EtherNet/IP - Modbus TCP option IPE002Z User Manual
Page 17
E6581741
- 16 -
3.2.4.3. fa23 (Communication command 2)
bit Function
0
1
Note
0 (Reserved)
-
-
-
1
Electric power quantity
reset
OFF Reset
Electric power quantity (fe76,
fe77
) reset
2 (Reserved)
-
-
-
3 (Reserved)
-
-
-
4 (Reserved)
-
-
-
5 (Reserved)
-
-
-
6 (Reserved)
-
-
-
7
Maximum deceleration
forced stop
Normal Enabled
-
8
Acceleration/decele-
ration selection 1
9
Acceleration/decele-
ration selection 2
00: Acceleration/deceleration 1
01: Acceleration/deceleration 2
10: Acceleration/deceleration 3
Select acceleration/deceleration
1-3 by combination of two bits..
AD1: acc, dec
AD2: f500, f501
AD3: f510, f511
10 (Reserved)
-
-
-
11 (Reserved)
-
-
-
12
OC stall level switch
OC stall 1
OC stall 2
OC stall 1: f601
OC stall 2: f185
13 (Reserved)
-
-
-
14 (Reserved)
-
-
-
15 (Reserved)
-
-
-
Note: Set 0 to reserved bit.