5.1.11. Instance 105: TOSHIBA specific output
Instance 105 mapping
Byte
Bit 7
Bit 6
Bit 5
Bit 4 Bit
3 Bit
2 Bit
1 Bit
0
0
1
Function code (Read / Write) (*1)
2
Index (Low byte)
3
Index (High byte)
4
Data (Low byte)
5
Data (High byte)
6
c001
Command data (Low byte)
7
c001
Command data (High byte)
8
c002
Command data (Low byte)
9
c002
Command data (High byte)
10
c003
Command data (Low byte)
11
c003
Command data (High byte)
12
c004
Command data (Low byte)
13
c004
Command data (High byte)
14
c005
Command data (Low byte)
15
c005
Command data (High byte)
16
c006
Command data (Low byte)
17
c006
Command data (High byte)
Refer to "Scanner Address (c001 – c006) and Scanner Value (c041 – c046: details of
command data)."
5.1.12. Instance 155: TOSHIBA specific input
Instance 105 mapping
Byte
Bit 7
Bit 6
Bit 5
Bit 4 Bit
3 Bit
2 Bit
1 Bit
0
0
1
Function code (Read / Write) results
2
Index (Low byte)
3
Index (High byte)
4
Data (Low byte)
5
Data (High byte)
6
c021
Command data (Low byte)
7
c021
Command data (High byte)
8
c022
Command data (Low byte)
9
c022
Command data (High byte)
10
c023
Command data (Low byte)
11
c023
Command data (High byte)
12
c024
Command data (Low byte)
13
c024
Command data (High byte)
14
c025
Command data (Low byte)
15
c025
Command data (High byte)
16
c026
Command data (Low byte)
17
c026
Command data (High byte)
Refer to "Scanner Address (c021 – c026) and Scanner Value (c061 – c066: details of
command data)."
(*1): Please set the function code as follow.
Read: 0x00
Write: 0x80