7.3.3
Fibre Channel Right
This value defines whether a Fibre Channel Option is currently installed on the right
side of a dual bay library.
Fibre Channel Right
is a multiple-choice value with the options listed below:
NONE
No Fibre Channel Option
A
Fibre Channel hatch with one Fibre Channel (1Gb) and three
SCSI (Ultra2)
B
Fibre Channel with two Fibre Channels (2Gb) and six SCSI (Ul-
tra160)
C
Fibre Channel hatch with one Fibre Channel (2Gb) and two SCSI
(Ultra160)
7.4
Configuration\Advanced\Fibre Channel (Left or Right) Menu
CA•••••Fibre•Channel
CA•••••••••••FC•Left
CA••••••••••FC•Right
Alarm: NO
Ch0 FC Speed: AUTO
Ch1 FC Speed: AUTO
Ch0 SCSI ID: dd
Ch1 SCSI ID: dd
Ch2 SCSI ID: dd
Ch3 SCSI ID: dd
Ch4 SCSI ID: dd
Ch5 SCSI ID: dd
Ch0 SCSI Speed:160
Ch1 SCSI Speed:160
Ch2 SCSI Speed:160
Ch3 SCSI Speed:160
Ch4 SCSI Speed:160
Ch5 SCSI Speed:160
CLEAR LOG
Router LUN: SOFT
•Set Time
This menu permits control of certain aspects of the Fiber Channel Options operation.
7.4.1
Alarm
An audible alarm on the Fibre Channel Option interface is sounded if a warning or er-
ror event is reported by the Fibre Channel Option.
YES
If the
Alarm
value is set to
YES
, the audible alarm is enabled.
NO
If the
Alarm
value is set to
NO
, the audible alarm is disabled.