7.3
Configuration\Advanced\Changer\Mechanics Menu
CA•Changer•Mechanics
Model: 4210
BCR: NONE
Carriage B
Door Lock: NONE
FibreCh: C
FC Left: NONE
FC Right: NONE
I/O Port: A
Q-Link: A
Shuttle: NONE
The
Configuration\Advanced\Changer\Mechanics
menu describes the
hardware configuration of the TLS. The values in this menu are factory-set to reflect
the unit's configuration at the time of shipping and are not changeable.
7.3.1
Fibre Channel
This value defines whether a Fibre Channel Option is currently installed on a single
bay library.
Fibre Channel
is a multiple-choice value with the options listed below:
NONE
No Fibre Channel Option
A
Fibre Channel hatch with one Fibre Channel (1Gb) and three
SCSI (Ultra2)
B
Fibre Channel with two Fibre Channels (2Gb) and six SCSI (Ul-
tra160)
C
Fibre Channel hatch with one Fibre Channel (2Gb) and two SCSI
(Ultra160)
7.3.2
Fibre Channel Left
This value defines whether a Fibre Channel Option is currently installed on the left
side of a dual bay library.
Fibre Channel Left
is a multiple-choice value with the options listed below:
NONE
No Fibre Channel Option
A
Fibre Channel hatch with one Fibre Channel (1Gb) and three
SCSI (Ultra2)
B
Fibre Channel with two Fibre Channels (2Gb) and six SCSI (Ul-
tra160)
C
Fibre Channel hatch with one Fibre Channel (2Gb) and two SCSI
(Ultra160)
501440 Rev. J
The Configuration Menu
7-5