1 installation, Installation -10 – Qualstar 501440 Rev. G User Manual
Page 23
4.5.1
Installation
The following steps outline the actions necessary to install a Fibre Channel Option
onto a library.
1.
Remove power from the TLS: first turn the power switch off and then remove the
power cord.
2.
Using a Phillips screwdriver remove the six screws securing the service panel on
the rear of the library – refer to Figure 4-8. Depending of the model of library,
the service panel may not have ventilation slots. Care must be taken to not re-
move the four screws securing the heatsink panels. Save the service panel for
possible future use.
Phillips Screws (6)
Do not remove
these screws
Do not remove
these screws
Figure 4-8 Service Panel
3.
Place the lower lip of the FCO inside the bottom edge of the service panel open-
ing and tilt the FCO upwards, making sure that the heatsink panel screws align
with the openings in the FCO. See Figure 4-9. The hinge surfaces should rest flat
against the rear of the library.
4.
Using a Phillips screwdriver, secure the FCO to the rear of the library at the
FCO’s two top captive screws. See Figure 4-9.
5.
Using two of the screws that were removed with the service panel, attach the
FCO’s two hinges to the rear of the library. See Figure 4-9.
FCO Type C Installation
501440 Rev. J
4-10