Qualstar 501440 Rev. G User Manual
Page 37

5.5
Cabling for TLS-412xxx Libraries with AIT-3 Tape Drives
Connectors on Rear of FCO Connectors on Rear of TLS-412xxx
SCSI Channel 0
Left Medium Changer
Left Tape Drive 1 (LT1)
Left Tape Drive 2 (LT2)
SCSI Channel 1
Left Tape Drive 3 (LT3)
Left Tape Drive 4 (LT4)
SCSI Channel 2
Left Tape Drive 5 (LT5)
Left Tape Drive 6 (LT6)
SCSI Channel 3
Right Tape Drive 1 (RT1)
Right Tape Drive 2 (RT2)
SCSI Channel 4
Right Tape Drive 3 (RT3)
Right Tape Drive 4 (RT4)
SCSI Channel 5
Right Tape Drive 5 (RT5)
Right Tape Drive 6 (RT6)
Serial
DB9 (Right Executive IV, SERL A)
Table 5-4 Preferred Fibre Channel Option Cable Connections for 12 AIT-3 Tape Drives
The following steps outline the actions necessary to connect the cables from the FCO
to the TLS-412xxx with AIT-3 tape drives installed. Please see Figure 5-4 and Figure
5-5. If AIT-5 tape drives are installed see Sections 5.6 and 5.7.
1.
Remove power from the TLS: first turn the power switch off and then remove the
power cord.
2.
Remove power from the FCO: first turn the power switch off and then remove
the power cord.
3.
Connect a SCSI Cable from the SCSI Channel 0 connector on the FCO to connec-
tor A on the left side on the TLS.
4.
Connect the SCSI Bridge Cable (very short cable) from connector B to C.
5.
Connect a SCSI Cable from the SCSI Channel 1 connector on the FCO to connec-
tor E.
6.
Connect a SCSI Cable from the SCSI Channel 2 connector on the FCO to connec-
tor G.
7.
Attach an LVD SCSI terminator at connectors D, F and H.
8.
Connect a SCSI Cable from the SCSI Channel 3 connector on the FCO to connec-
tor I on the right side on the TLS.
9.
Connect a SCSI Cable from the SCSI Channel 4 connector on the FCO to connec-
tor K.
501440 Rev. J
FCO Type B Installation