beautypg.com

NEC 320Fc User Manual

Page 97

background image

Viewing Active Upgrade Process Status

Performing the Upgrade

4-27

Related Topics

“Activity Log” on page 4-21

“Saving the Activity Log to a File” on page 5-1

Troubleshooting

Table 4-6. Status: Partner State

Partner State

Description

DC On

The partner operating system is shut down, but system power
is still on.

DC Off

The partner operating system is shut down and system power
is off (but the system still has housekeeping power).

BIOS POST

The partner system is performing a BIOS Power On Self Test
(POST).

Hung: BIOS POST

The partner system hung in the BIOS POST.

OS Booting

The partner operating system is booting.

Hung: OS Booting

The partner system hung in the boot process.

OS Up

The partner operating system is up. (However, the system
might not be available for use until other system resources
finish loading.)

Hung: OS Up

The partner operating system is hung.

OS Rebooting

The partner operating system is rebooting.

Hung: OS Rebooting

The partner system hung while rebooting.

OS Shutting Down

The partner operating system is shutting down.

Hung: OS Shutting Down

The partner system hung while the operating system was
shutting down.

State Sensitive Recovery:
NMI issued

The partner operating system has crashed.

State Sensitive Recovery:
Reset

The system controller is performing a hard reset of the partner
system.