beautypg.com

NEC Disk Array Controller N8103-89 User Manual

Page 121

background image

101

FastBuild (tm) Utility (c) xxxx-xxxx Promise Technology, Inc.


LD No RAID Mode Total Drv Capacity(MB) Status

LD 1 RAID 5 4 80000 Functional

Stripe Block: 64 KB Cache Mode: AutoSwitch

[ View LD Definition Menu ]

Any Key to Continue.......


Channel:ID Drive Model Capacity (MB) Assignment
1:Mas MAXTOR 6Y080MO 80001 N
2:Mas MAXTOR 6Y080MO 80001 N
3:Mas MAXTOR 6Y080MO 80001 N
4:Mas MAXTOR 6Y080MO 80001 N

[ Drives Assignments ]

Check

The capacity of a logical drive seems smaller on OS then that on FastBuild
Utility. This is because FastBuild Utility converts 1 GB to 10,003 bytes while
OS converts 1 GB to 10,243 bytes.

14.

To create another logical drive continuously, follow the same procedure again.

15.

After the settings of logical drives are completed, exit from FastBuild Utility and
reboot the server.

16.

While the server is rebooted, the POST screen shown below appears. Make sure
that "STATUS" is set to "Functional."

Ex: Logical drive in RAID5 configured by 4 HDDs

FT SX4100 (tm) BIOS Version x.x.xxxx.xx

(c) xxxx-xxxx Promise Technology, Inc. All rights reserved.

Installed ECC DIMM 64M

ID MODE SIZE TRACK-MAPPING STATUS

1 3+0 RAID 5

239799M 29153/255/63 Functional

Press to enter FastBuild (tm) Utility...