beautypg.com

Figure 5-22: ip connectivity screen, Table 5-8: ip connectivity parameters – Nortel Networks Mediant TP-1610 SIP User Manual

Page 72

background image

Mediant 2000 SIP

Mediant 2000 SIP User’s Manual

72

Document #: LTRT-72504

Note:

The information in columns ‘Quality Status’ and ‘Quality Info.’ (per IP address)
is reset if two minutes elapse without a call to that destination.

To view the IP connectivity information, take these 2 steps:

1.

Set ‘AltRoutingTel2IPEnable’ to 1 or 2.

2.

Open the ‘IP Connectivity’ screen (Status & Diagnostics menu > Gateway Statistics
submenu > IP Connectivity); the ‘IP Connectivity’ screen is displayed (

Figure

5-22

).

Figure

5-22: IP Connectivity Screen

Table

5-8: IP Connectivity Parameters

Column Name

Description

IP Address

IP address defined in the destination IP address field in the Tel to IP Routing table.
or
IP address that is resolved from the host name defined in the destination IP address field in the
Tel to IP Routing table.

Host Name

Host name (or IP address) defined in the destination IP address field in the Tel to IP Routing
table.

Connectivity Method

The method according to which the destination IP address is queried periodically (currently
only by ping).

Connectivity Status

Displays the status of the IP address’ connectivity according to the method in the ‘Connectivity
Method’ field.
Can be one of the following:

OK

= Remote side responds to periodic connectivity queries.

Lost

= Remote side didn’t respond for a short period.

Fail

= Remote side doesn’t respond.

Init

= Connectivity queries not started (e.g., IP address not resolved).

Disable

= The connectivity option is disabled (‘AltRoutingTel2IPMode’ equals 0 or 2).

Quality Status

Determines the QoS (according to packet loss and delay) of the IP address.
Can be one of the following:

Unknown

= Recent quality information isn’t available.

OK

Poor

Note 1:

This field is applicable only if the parameter ‘AltRoutingTel2IPMode’ is set to 2 or 3.

Note 2:

This field is reset if no QoS information is received for 2 minutes.