Ss7 parameters, J.3 ss7 parameters – Nortel Networks Mediant TP-1610 SIP User Manual
Page 233

Mediant 2000 SIP User’s Manual
J. SS7 Tunneling
Version 4.4
233
July 2005
J.3 SS7
Parameters
The parameters in
below configure all MTP attributes simultaneously. To set each MTP
attribute individually, add _xx (xx equals the element number in the range of 0 to 2) to the end of
the ini file field name.
Table J-1: SS7 Parameters (continues on pages 233 to 234)
ini File Parameter Name
Description
SS7_MTP2_Param_AERM_TIE
Defines the SS7 alignment emergency error rate threshold.
The valid range is 0 to 10.
The default value is 1.
SS7_MTP2_Param_AERM_TIN
Defines the SS7 alignment normal error rate threshold.
The valid range is 0 to 20.
The default value is 4.
SS7_MTP2_Param_Error_Correction_
Method
Defines the SLI error correction method.
0 = Basic (default)
B = Basic
P = PCR (Preventive Cyclic Retransmission)
SS7_MTP2_Param_IAC_CP
Defines the number of aborted proving attempts before sending an out-of-
service to MTP-3.
The valid range is 0 to 10.
The default value is 5.
SS7_MTP2_Param_Link_Rate
Defines the SS7 SLI Link Rate.
Choose either:
0 = 64 kbps (default)
A = 64 kbps
D = 56 kbps
SS7_MTP2_Param_LSSU_Length
Defines the SS7 MTP2 LSSU length as 1 or 2 (bytes).
The valid range is 1 to 2.
The default value is 1.
SS7_MTP2_Param_Octet_Counting
Defines the SS7 MTP2 Octet received while the OCTET is in counting mode
(# of Octets received - N Octets - while in Octet counting mode).
The valid range is 0 to 256.
The default value is 16.
SS7_MTP2_Param_SUERM_SU_D
Defines the SS7 Signal Unit error rate monitor D threshold.
The valid range is 0 to 256.
The default value is 256.
SS7_MTP2_Param_SUERM_T
Defines the SS7 SUERM (Signal Unit Error Rate Monitor) T threshold.
The valid range is 0 to 256.
The default value is 64.
SS7_MTP2_Param_Timer_T1
Defines the SS7 MTP2 T1 alignment ready timer (in msecs).
The valid range is 0 to 100000.
The default value is 50000.
SS7_MTP2_Param_Timer_T2
Defines the SS7 MTP2 T2 unaligned timer (in msecs).
The valid range is 0 to 200000.
The default value is 150000.
SS7_MTP2_Param_Timer_T3
Defines the SS7 MTP2 T3 timer aligned.
The valid range is 0 to 20000.
The default value is 2000.
SS7_MTP2_Param_Timer_T4E
Defines the SS7 MTP2 T4e Emergency proving period timer (msec).
The valid range is 0 to 5000.
The default value is 500.
SS7_MTP2_Param_Timer_T4N
Defines the SS7 MTP2 T4n Nominal proving period timer.
The valid range is 0 to 15000.
The default value is 8200.
SS7_MTP2_Param_Timer_T5
Defines the SS7 MTP2 Sending SIB timer.
The valid range is 0 to 2400.
The default value is 120.