beautypg.com

Receive characteristics, Worst-case power budget and penalties, Table b-3 – Nortel Networks 450 User Manual

Page 243

background image

Gigabit Fiber Optical Characteristics

302401-D Rev 00

B-3

Receive Characteristics

Table B-3

lists the receive characteristics for the 1000BASE-SX models:

Worst-Case Power Budget and Penalties

Table B-4

lists the worst-case power budget and penalties for the 1000BASE-SX

models:

Table B-3.

1000BASE-SX Receive Characteristics

Description

62.5 Micron
Multimode Fiber

50 Micron
Multimode Fiber

Units

Signaling Speed (range)

1.25 ± 100 ppm

1.25 ± 100 ppm

GBd

Wavelength (range)

770 to 860

770 to 860

nm

Average receive power (maximum)

0

0

dBm

Receive sensitivity

– 17

– 17

dBm

Return loss (minimum)

12

12

dB

Stressed receive sensitivity

1

,

2

1 Measured with conformance test signal at TP3 for BER = 10

–12

at the eye center.

2 Measured with a transmit signal having a 9 dB extinction ratio. If you use another extinction ratio, correct the stressed

receive sensitivity according to the extinction ratio penalty.

– 12.5

– 13.5

dBm

Receive electrical 3 dB upper cutoff frequency
(maximum)

1500 1500

MHz

Vertical eye-closure penalty

3

3 Vertical eye-closure penalty is a test condition for measuring stressed receive sensitivity. It is not a required

characteristic of the receiver.

2.60

2.20

dB

Note:

The link power penalties (

Table B-4

) are used for link power budget

calculations only. They are not requirements and are not meant to be tested.

kombk.book Page 3 Tuesday, June 29, 1999 3:25 PM