Receive characteristics, Worst-case power budget and penalties, Table b-3 – Nortel Networks 450 User Manual
Page 243
Gigabit Fiber Optical Characteristics
302401-D Rev 00
B-3
Receive Characteristics
lists the receive characteristics for the 1000BASE-SX models:
Worst-Case Power Budget and Penalties
lists the worst-case power budget and penalties for the 1000BASE-SX
models:
Table B-3.
1000BASE-SX Receive Characteristics
Description
62.5 Micron
Multimode Fiber
50 Micron
Multimode Fiber
Units
Signaling Speed (range)
1.25 ± 100 ppm
1.25 ± 100 ppm
GBd
Wavelength (range)
770 to 860
770 to 860
nm
Average receive power (maximum)
0
0
dBm
Receive sensitivity
– 17
– 17
dBm
Return loss (minimum)
12
12
dB
Stressed receive sensitivity
1
,
2
1 Measured with conformance test signal at TP3 for BER = 10
–12
at the eye center.
2 Measured with a transmit signal having a 9 dB extinction ratio. If you use another extinction ratio, correct the stressed
receive sensitivity according to the extinction ratio penalty.
– 12.5
– 13.5
dBm
Receive electrical 3 dB upper cutoff frequency
(maximum)
1500 1500
MHz
Vertical eye-closure penalty
3
3 Vertical eye-closure penalty is a test condition for measuring stressed receive sensitivity. It is not a required
characteristic of the receiver.
2.60
2.20
dB
Note:
The link power penalties (
) are used for link power budget
calculations only. They are not requirements and are not meant to be tested.
kombk.book Page 3 Tuesday, June 29, 1999 3:25 PM