Nortel Networks Sun Fire V210 (RoHS) User Manual
Page 78

NN42020-310 MCS 5100 3.5 Standard 1.0 June 2006
78
Copyright © Nortel Networks Limited 2006
3
Please enter the correct number of the load to
deploy:
Example
[@micromgmt]/export/home/nortel:=>
mgmtdeploy.pl
Obtaining input required to deploy and
configure the mgmtsvr bundle
Please enter all IP addresses in
dot-notation format
==========================================
Querying DSM for available loads
Select a mgmtsvr load from the following list
[1] mgmtsvr_all-micro_ims_3.0_buildxxxx
[2] mgmtsvr_all-small_ims_3.0_buildxxxx
[3] mgmtsvr_all_ims_3.0_buildxxxx
Please enter the number [1] of the load to
deploy: 1
4
Is the database replicated?
N [Enter]
5
Enter Machine Logical IP Address - Primary DB:
Example: 120.120.13.22
6
Enter the Machine Logical IP Address - Mgmtsvr:
Example: 120.120.13.22
ATTENTION
When selecting the management server load, always select the
load that contains the word "micro" in it. If the non-micro load is
selected, the installer will receive an Out Of Memory error.
The server load names are:
• mgmtsvr_all-mico-ims — for a 2-server V210 installation.
• mgmtsvr_all-small-ims — for a 4-server V210 installation.
• mgmtsvr_all-ims — for an 8-server V210 installation.