Nortel Networks Sun Fire V210 (RoHS) User Manual
Page 61

MCS 2-server Sun Fire V210 (RoHS) Solaris Installation and Commissioning Guide
61
Copyright © Nortel Networks Limited 2006
5
You will see the following message:
You have chosen to configure NTP as follows:
Type of server: Application
NTP SOURCE (Management IP address):
120.120.13.22
NTP SOURCE (Accounting IP address):
120.120.13.22
Is the above configuration correct (y/n):
Select Y to continue or N to change.
6
Wait until you see the following message:
You are now configuring IPMP (Multipathing)
Please have the Application Servers (Appsvr,
IPCM, WebSvr, WebClientMgr) Physical IP
addresses and the Machine Logical IP address
ready. Have 6 IP addresses that can be used as
ping buddies. Recommendations for ping buddies
are provided.
7
Press Enter to continue.
8
When you see the IP multipathing configuration for Sun Solaris
information appear, press Enter to accept it or type in a preferred
setting. The default failover timeout is set to 1000mSec.
9
Enter the primary machine physical IP address for the bge0
interface:
Example: 120.120.13.23
10
Enter the secondary machine physical IP address for the bge1
interface:
Example: 120.120.13.24
11
Enter the
that are the ping targets.
Note: Do not enter the IP address of the server you are
working on.
IP Multipathing needs a set of reliable hosts to ping against.
Select a set of three IP addresses in this subnet that belong to
reliable nodes (such as fault tolerant servers). Select the three
nodes from the following list, in order of preference:
For IPMP GROUPS:
•
Machine Logical IP address of the database server
•
Machine Logical IP address of the Management server