Lcot dtmf minimum duration [412, Lcot cpc signal detection time—outgoing [413, Lcot cpc signal detection time—incoming [414 – Panasonic HYBRID IP-PBX KX-TDA200 User Manual
Page 324: Lcot reverse circuit [415, Lcot pause time [416, Lcot flash/recall time [417, Lcot disconnect time [418, Lcot pause time [416]), Lcot disconnect time [418]), Lcot flash/recall time
![background image](/manuals/185893/324/background.png)
3.3 PT Programming
324
Feature Guide
LCOT DTMF Minimum Duration [412]
LCOT CPC Signal Detection Time—Outgoing [413]
LCOT CPC Signal Detection Time—Incoming [414]
LCOT Reverse Circuit [415]
LCOT Pause Time [416]
LCOT Flash/Recall Time [417]
LCOT Disconnect Time [418]
[412]
80/160 ms
END
SELECT
ENTER
ENTER
01–10
Slot No.
01–16
Port No.
[413]
0: None/1: 6.5/
2–113: (N–1)×8 ms
END
ENTER
ENTER
01–10
Slot No.
01–16
Port No.
Mode No.
[414]
END
ENTER
ENTER
0: None/1: 6.5/
2–113: (N–1)×8 ms
01–10
Slot No.
01–16
Port No.
Mode No.
[415]
Disable/
Outgoing/Both Call
END
SELECT
ENTER
ENTER
01–10
Slot No.
01–16
Port No.
[416]
1.5/2.5/
3.5/4.5 s
END
SELECT
ENTER
ENTER
01–10
Slot No.
01–16
Port No.
[417]
None/80/96/112/
300/600/900/
1200 ms/option
END
SELECT
ENTER
ENTER
01–10
Slot No.
01–16
Port No.
[418]
0.5/1.5/2.0/
4.0/12.0 s
END
SELECT
ENTER
ENTER
01–10
Slot No.
01–16
Port No.