Appendix B – EMC Installation Guidelines

4 9

Ground Strap

(connect to TH1)

I/O Flat Cable

User provided
power from a
clean DC power
supply (use
twisted pair cable)

Remove
Paint

Remove paint
if mounting on
this surface

VM50

Programmable
I/O Cable

Limits Cable

Communications Cable

Triggers Cable

Drive Cable

Encoder Cable

Braided-screen
Cables

Figure 3. EMC Connections for OEM6250