Chapter 1. Installation

7

Motor Drivers

WARNING

REMOVE DC POWER FIRST before connecting or disconnecting the drive.

CONNECTIONS & INTERNAL SCHEMATICS

OEM6250

Drive

Motor

Internal Schematics

Analog Ground
(AGND)

6.8 K

W

DRIVE Connector

SHLD
COM
SHTNC
SHTNO
DFT
AGND
RSVD
CMD–
CMD+

AGND

Chassis Ground

AGND

+

-

Command +

Closed if

DRIVE¯

Open if

DRIVE1

Solid State Relay

Open if

DRIVE¯

Closed if

DRIVE1

DRIVE 1
DRIVE 2

Maximum recommended cable
length is 15 feet (4.56 m).
Use 22 AWG wire.

AUX

47 K

W

74HCxx

DFT (Drive Fault) input:
HCMOS compatible switching: low

£

1.00V, high

³

3.25V.

Voltage range = 0-24V.

+5VDC