beautypg.com

End-of-travel & home limit inputs, End-of-travel and home limit inputs, Connections & internal schematics – Parker Hannifin SERVO CONTROLLER OEM6250 User Manual

Page 18: Pin outs & specifications

background image

1 2

OEM6250 Installation Guide

End-of-Travel and Home Limit Inputs

N O T E S

CAUTION: As shipped from the factory, the limit inputs are pulled up to +5V through the R45 resistor. To

use a voltage reference other than +5V, first remove R45 and then use either the on-board +5V terminal
or an external power supply to power the AUX-P pull-up resistor (using both will damage the OEM6250).

• Motion will not occur on an axis until you do one of the following:

- Install end-of-travel (POS & NEG) limit switches.
- Disable the limits with the

LH¯

command (recommended only if load is not coupled).

- Change the active level of the limits with the

LHLVL

command.

• Refer to the

Basic Operation Setup chapter in the 6000 Series Programmer’s Guide for in-depth

discussions about using end-of-travel limits and homing.

CONNECTIONS & INTERNAL SCHEMATICS

TRG-B
GND
OUT-A
OUT-B
GND
ENBL
+5V
AUX-P

6.8 K

W

R45

(0 K

W

)

47 K

W

74HCxx

Digital
GND

Internal Schematic

POS & NEG connected to GND

(normally-closed switches).

Mount each switch such that the load forces it to open before it
reaches the physical travel limit (leave enough room for the load to
stop). When the load opens the switch, the axis stops at the decel
value set with the

LHAD

command. The motor will not be able to

move in that same direction until you execute a move in the opposite
direction and clear the limit by closing the switch (or you can disable
the limits with the

LH¯

command, but this is recommended only if the

motor is not coupled to the load). The active level (default is active
low) can be changed with the

LHLVL

command.

HOM connected to GND

(normally-open switch).

The home limit input is used during a homing move, which is initiated
with the

HOM

command. After initiating the homing move, the controller

waits for the home switch to close, indicating that the load has reached
the “home” reference position. The active level (default is active low) can
be changed with the

HOMLVL

command. You can also use an encoder’s

Z channel pulse, in conjunction with the home switch, to determine the
home position (this feature is enabled with the

HOMZ1

command).

Chassis
Ground

Digital
GND

LIMITS Connector

1POS
1NEG
1HOM
GND
2POS
2NEG
2HOM
GND
SHLD

AUX Connector

All limit inputs share the
same circuit design.

Remove R45 before
connecting AUX-P to
an external 5-24VDC
supply (sink current)
or to the GND
terminal (source
current). Failure to
remove R45 first
will damage the
OEM6250.

+5VDC

OEM6250

AUX

Connector

R45

AUX-P

Location of
resistor R45.

As shipped from the factory, AUX-P is internally connected to +5V via resistor R45 (input is sinking current).
To make the Limit inputs sink current to a supply other than +5V, first remove R45 and then connect an
external 5-24V supply to the AUX-P terminal. To source current, first remove R45 and then connect the AUX-P
terminal to the GND terminal. CAUTION: Failure to remove R45 before connecting AUX-P to an external
supply or to the GND terminal or to the +5V terminal will damage the OEM6250.

NOTE: AUX-P (and R45) are also used by the ENBL & TRG inputs.

HCMOS compatible (switching levels: low

£

1.00V, high

³

3.25V). Voltage range = 0-24V.

LIMITS

Connector

PIN OUTS & SPECIFICATIONS

(LIMITS Connector)

Pin Name

In/Out

Description

Specification for all limit inputs

9
8
7
6
5
4
3
2
1

1POS
1NEG
1HOM
GND
2POS
2NEG
2HOM
GND
SHLD

IN
IN
IN

IN
IN
IN

Positive-direction end-of-travel limit input, axis 1.
Negative-direction end-of-travel limit input, axis 1.
Home limit input, axis 1.
Digital ground.
Positive-direction end-of-travel limit input, axis 2.
Negative-direction end-of-travel limit input, axis 2.
Home limit input, axis 2.
Digital ground.
Chassis ground (earth).

• HCMOS compatible (Low

£

1.00V, High

³

3.25V) with internal

6.8 K

W

pull-up resistor to AUX-P terminal. As shipped from the

factory, AUX-P is internally connected to +5V via resistor R45.
To connect AUX-P to a supply other than +5V or to connect to
ground, first remove R45 and then connect AUX-P to an external
5-24V supply or to the GND terminal. Voltage range for these
inputs is 0-24V.

• Active level for HOM is set with

HOMLVL

(default is active low,

requires n.o. switch).

• Active level for POS & NEG is set with

LHLVL

(default is active

low, requires n.c. switch).