beautypg.com

Rp240 remote operator panel, Input power (+5vdc ±5%, 4a minimum), Input power – Parker Hannifin SERVO CONTROLLER OEM6250 User Manual

Page 26

background image

2 0

OEM6250 Installation Guide

RP240 Remote Operator Panel

RP240

SHLD
Tx
Rx
GND
+5V

GND
Rx
Tx
+5V

RP240 Back Plane

Input Power

(+5VDC

±

5%, 4A minimum)

Current Requirements

The current requirements for the +5VDC supply depend on the type and amount of I/O used.
At the minimum current (4A for 5VDC supply), the OEM6250 should supply sufficient +5V
power for:

Two encoders

A joystick

All home and end-of-travel limits

The two trigger inputs

An RP240 (100mA)

You may need additional power (from an external 5-24VDC supply) for the programmable
inputs and outputs, depending on how and what they are connected to. To provide additional
power for the programmable inputs, be sure to remove the R12 resistor first before
connecting the external power supply to the IN-P terminal; for the programmable outputs,
remove R13 first before connecting the external supply to the OUT-P terminal.

External

5VDC Supply

(

±

5%, 4A minimum)

1

5

+15V NC -15V GND +5V

OEM6250

No Connect