Rp240 remote operator panel, Input power (+5vdc ±5%, 4a minimum), Input power – Parker Hannifin SERVO CONTROLLER OEM6250 User Manual
Page 26
2 0
OEM6250 Installation Guide
RP240 Remote Operator Panel
RP240
SHLD
Tx
Rx
GND
+5V
GND
Rx
Tx
+5V
RP240 Back Plane
Input Power
(+5VDC
±
5%, 4A minimum)
Current Requirements
The current requirements for the +5VDC supply depend on the type and amount of I/O used.
At the minimum current (4A for 5VDC supply), the OEM6250 should supply sufficient +5V
power for:
•
Two encoders
•
A joystick
•
All home and end-of-travel limits
•
The two trigger inputs
•
An RP240 (100mA)
You may need additional power (from an external 5-24VDC supply) for the programmable
inputs and outputs, depending on how and what they are connected to. To provide additional
power for the programmable inputs, be sure to remove the R12 resistor first before
connecting the external power supply to the IN-P terminal; for the programmable outputs,
remove R13 first before connecting the external supply to the OUT-P terminal.
External
5VDC Supply
(
±
5%, 4A minimum)
1
5
+15V NC -15V GND +5V
OEM6250
No Connect