beautypg.com

Backup status screens – Paradyne 3910 User Manual

Page 59

background image

Status Branch

4-9

3910-A2-GN32-40

September 1998

Table 4-2

Backup Status Screens

Active Line

1st Screen Display

Inactive Line

2nd Screen Display

Possible Inactive/Backup Line Condition

Line=Pri 4w APL
or
Line=Pri 2w APL

Bckup:2wAPL=XXXX
or
Bckup : Dial =(blank)

Good indicates that line continuity is detected.
Bad indicates that line continuity is not detected.
???? indicates that the line condition is unknown
(Backup Facility Check is making its first
determination of the line conditions since the last
retrain).
blank indicates that the Backup Line Check option is
disabled.

Line=Bkup 2w APL
or
Line = Dial Backup

Pri 4w APL =XXXX
or
Pri 2w APL =XXXX

Good indicates the line condition is good.
Bad indicates the line condition is bad.
???? indicates the line condition is unknown (Lease
Lookback has not had enough time to make an initial
appraisal of the line conditions since the last retrain).
blank indicates the Lease Loopback option is
disabled.

Line=Dial Only

No second screen
display.

NOTE: When the modem is configured for Dial Only,

there is no backup.

NOTE: The leased-line interface is disabled when the

factory default options are loaded from the
Async Dial, Sync Dial, or UNIX Dial

templates.

Line=No Sync

No second screen
display.

NOTE: No Sync appears when the modem is not

trained on either the primary or backup line

facility.

To exit this function and remain in the Status branch, press the

key. To exit and return to the

Top-Level menu, press the

key.