Miscellaneous Configuration Options
NMS_Call_Msgs: CallCnct&Prg
Nxt CallCnct&Prg Disable CallCnctOnly CallProgOnly
NMS Call Messages. Determines if the modem status and/or call summary information is sent to the NMS.
The modem can itemize status, such as CallProgress messages, or it can report a summary of activity, such
as Call Connect messages, to the NMS.
H
Call Connect & Progress
Enables both Call Connect and Call Progress information to be transmitted to the NMS.
H
Disable
Modem status and call summary information is not sent to the NMS.
H
Call Connect Only
The modem accumulates call statistics over a period of time and then transmits a summary of these
statistics to the NMS. The NMS uses this data to produce utilization reports.
H
Call Progress Only
The modem transmits detailed modem status information to the NMS. These messages include any
events that can display on the LCD.
NOTE: For 6800 Series NMS applications, Disable must be selected.
The AT commands are S-Register S66=
n where n is 0 for Call Connect & Progress, 1 for Disable, 2 for Call
Connect Only, and 3 for Call Progress Only.
NetworkPosition: Tributary
End Tributary Control
Network Position Identification. Each modem must be identified either as a control modem or a tributary
modem.
NOTE: Changes to this configuration option will cause the modem to reset.
NOTE: This configuration option is only applicable for leased-line network management applications.
For the Model 3910, Tributary is the factory default.
For the Model 3911, Control is the factory default.
The AT command for Tributary is S74=0.
The AT command for Control is S74=1.
NetMngmtAddress: 256
Nxt
"
256
This configuration option is not available in point-to-point tributaries.
Network Management Address. Determines the address used when accessing a modem from the NMS or
when using DCP functions that require network management addresses. Within a network link, a control
modem can communicate with a tributary modem by using the tributary modem’s network management
address. Each tributary modem must have a different network management address.
NOTE: Changes to this configuration option will cause the modem to reset.
NOTE: A point-to-point tributary is always Address 1.
Address values range from 001 to 256.
The AT command is S-Register S75=