beautypg.com

Valid ranges for vf thresholds – Paradyne 3910 User Manual

Page 136

background image

COMSPHERE 3900 Series Modems

7-16

September 1998

3910-A2-GN32-40

To correct the invalid VF threshold, press the

key to return to the VF Threshold

Edit/Save/Reset screen.

F1

VF Thresholds
Edit Save Reset

F2

F3

Select Reset to restore the original default values into memory.

Repeat the Edit and Save procedure until the VF threshold(s) is valid and the Save completes
successfully (Save Completed).

To exit this function and remain in the Control branch, press the

key. To exit and return to

the Top-Level menu, press the

key.

Table 7-1

Valid Ranges for VF Thresholds

VF Thresholds

Valid Ranges

Default Values

Receive Signal Level High

0 dBm to –15 dBm

Above –9 dBm

Receive Signal Level Low

–16 dBm to –50 dBm

Below –23 dBm

Signal to Noise Ratio

5 dB to 40 dB

Below 23 dB

Non-Linear Distortion

15 dB to 50 dB

Below 30 dB

Retrains

1 to 256 trains

15 trains per 15 minutes

Signal Quality

Excellent (lowest)
Good
Fair
Poor
No Signal (highest)

Good

Near Echo

0

ā

—38 dBm

Above –20 dBm

Far Echo

0 —38 dBm

Above –20 dBm