AT Command Set and S-Registers

14-3

3910-A2-GN32-40

September 1998

Result Codes

Table 14-1 lists all valid result codes for the 391x Series modem.

Table 14-1

(1 of 2)

Result Codes

Numbers

(1)

Numbers

(2)

Word

Description

0

0

OK

Command executed

1

1

CONNECT

Modem connected to line

2

2

RING

Modem receiving a ring voltage from the VF line

3

3

NO CARRIER

Modem lost carrier signal, does not detect carrier
signal, or does not detect answer tone

4

4

ERROR

Invalid command

5

5

CONNECT 1200*

Connection at 1200 bps

6

6

NO DIALTONE*

No dial tone detected

7

7

BUSY*

Busy or trunk busy signal detected

8

8

NO ANSWER*

No “quiet” answer (@)

10

10

CONNECT 2400*

Connection at 2400 bps

11

11

CONNECT 4800*

Connection at 4800 bps

12

12

CONNECT 9600*

Connection at 9600 bps

13

16

CONNECT 12000*

Connection at 12,000 bps

14

13

CONNECT 14400*

Connection at 14,400 bps

15

14

CONNECT 19200**

Connection at 19,200 bps

16

15

CONNECT 7200*

Connection at 7200 bps

17

17

CONNECT 16800**

Connection at 16,800 bps

19

19

CONNECT 300*

Connection at 300 bps

20

10

CONNECT 2400/ EC***

Connection at 2400 bps with error control

21

11

CONNECT 4800/ EC***

Connection at 4800 bps with error control

22

12

CONNECT 4800/ EC***

Connection at 4800 bps with error control

23

16

CONNECT 12000/ EC***

Connection at 12,000 bps with error control

24

13

CONNECT 14400/ EC***

Connection at 14,400 bps with error control

25

17

CONNECT 16800/ EC**

Connection at 16,800 bps with error control

26

15

CONNECT 7200/ EC***

Connection at 7200 bps with error control

27

5

CONNECT 1200/ EC*

Connection at 1200 bps with error control

* Only appears when the Extended Result Codes configuration option is enabled.

** Only appears when the Extended Result Codes configuration option is set for Use_DTE_Rate. This

displays the DTE data rate instead of the line rate.

*** Only appears when the Extended Result Codes configuration option is set for Add/EC. If this

configuration option is set for Add/V42, MNP, then either V42b, V42, MNP5, MNP4, MNP3, MNP2, or
NoEC appears.