Paradyne 3910 User Manual
Page 120
COMSPHERE 3900 Series Modems
6-6
September 1998
3910-A2-GN32-40
Press the
key until Acquire appears. Select Acquire.
NOTE
If an error message (OtherTestActive or Unable To Acquir)
appears on the second line of the LCD, move up one level in the
menu tree to clear the message and return to the PList Acquire
branch. The OtherTestActive message indicates that a test is
running which blocks the Acquire function. The Unable To Acquir
message indicates that the diagnostic network is in a busy state.
F1
Poll List:Acquir
Abort xxx yyy
F2
F3
The address field (xxx) increments sequentially from 001 to 256 as polls are transmitted from the
modem to the downstream modem(s). To be added to the modem’s poll list, the device must
respond to a poll after receiving its address. The Acquire function can be canceled by selecting
Abort.
The number field (yyy) indicates the total number of devices that responded to the modem’s
polls. These devices have been acquired for the poll list.
Select Abort or allow the function to complete.
F1
Poll List:Acquir
Num Acquired yyy
F2
F3
The number field (yyy) indicates the total number of devices acquired for the poll list.
To exit this function and remain in the PList branch, press the
key. To exit and return to the
Top-Level menu, press the
key.