COMSPHERE 392xPlus Modems

3-54

November 1996

3920-A2-GN31-30

Table 3-8

(2 of 2)

Valid Ranges for VF Thresholds

VF Thresholds

Default Values

Valid Ranges

Far Echo

0 –38 dBm

Above –20 dBm

Frequency Offset

1 Hz to 15 Hz

Above 4 Hz

Phase Jitter

1 degree to 45 degrees

Above 9 degrees

Phase Hits

1 to 255 hits

20 hits per 15 minutes

Impulse Hits

1 to 255 hits

20 hits per 15 minutes

Gain Hits

1 to 255 hits

20 hits per 15 minutes

Drop Outs

1 to 255 dropouts

20 dropouts per 15 minutes

Test Branch

The Test branch of the Top-Level menu allows you to initiate various modem tests. Use these tests
if you are having data communication problems, such as periodic character loss, random errors, or
constant format errors. By the process of elimination, you can usually isolate the fault in your
system.

There are six selections under Test: Abort, Self (Self-Test), Loc Analog Loop (Local Analog
Loopback), Rem Digital Loop (Remote Digital Loopback), Loc Digital Loop (Local Digital
Loopback), and Pattern. The only tests that can operate concurrently on a single modem are Pattern
with a Local Analog Loopback and Pattern with a Remote Digital Loopback. If any test is
operating, besides the two combinations just mentioned, it must be canceled before starting another
test.

The Test branch only initiates and cancels tests. If parameters need to be set, refer to the Tests
section in Chapter 4.