Paradyne 392xPLUS User Manual
Page 159
COMSPHERE 392xPlus Modems
4-42
November 1996
3920-A2-GN31-30
Table 4-8
(2 of 5)
DTE Dialer Configuration Options — Singleport Mode
A
AT Escape Char: 043 ASCI
Nxt
"
043 ASCI
This configuration option only appears when DTE Dialer Type is configured for AT.
AT Escape Character. The escape sequence (+++) allows you to move from Data mode to Command mode. Use the
ATO command to return to Data mode. The ASCII value of the escape character (43 ASCII) can be set to any ASCII
value from 0 ASCII to 255 ASCII. However, the escape character is disabled if a value greater than 127 ASCII is
entered. When disabled, the call must be disconnected to return to Command mode.
The AT command is S-Register S2=
n, where n is a value from 0 to 127.
The AT command to disable is S-Register S2=
n where
n is a value from 128 to 255. (When disabled, the modem cannot
return to Command mode unless disconnected.)
Escape GuardTim: 1sec
Nxt 1sec 200msec 400msec 600msec 800msec 2sec
This configuration option only appears if DTE Dialer Type is configured for AT.
Escape Guard Time. Determines the length of the required pause before and after the escape sequence is issued. The
guard time prevents the modem from interpreting data as the escape sequence characters.
The AT command is S-Register S12=
n, where n is a value from 0 to 255 in 20 millisecond increments.
BreakForceEscap: Disable
Nxt Disable Enable
This configuration option only appears when DTE Dialer Type is configured for AT.
Break Forces Escape. Determines whether or not the modem should enter Command mode when it receives a break
character from the DTE.
Disable – A break character is sent to the remote end.
Enable – Modem escapes into AT Command mode, and a break character is not sent to the remote end.
The AT commands for Enable are \K0, \K2, or \K4.
The AT commands for Disable are \K1, \K3, or \K5.
CommandCharEcho: Enable
Nxt Enable Disable
This configuration option only appears when DTE Dialer Type is configured for AT.
Command Character Echo. Controls whether or not characters are echoed back to the DTE when the modem is in
Command mode.
The AT command for Disable is E0.
The AT command for Enable is E1.
CarriageRtn Char: 013 ASCI
Nxt
"
013 ASCI
This configuration option only appears when DTE Dialer Type is configured for AT.
Carriage Return Character. Allows you to change the ASCII character used to terminate an AT command to any ASCII
value from 0 to 127.
The AT command is S-Register S3=
n, where n is a value from 0 to 127.
Backspace Char: 008 ASCI
Nxt
"
008 ASCI
This configuration option only appears when DTE Dialer Type is configured for AT.
Backspace Character. Sets the character used to perform a backspace in Command mode.
The AT command is S-Register S5=
n, where n is a value from 0 to 127.