Paradyne 392xPLUS User Manual
Page 193
COMSPHERE 392xPlus Modems
5-8
November 1996
3920-A2-GN31-30
Table 5-2
(3 of 9)
392x
Plus AT Commands
AT
Command
DCP LCD
Command
Sequence
Description
X
n
Extended Result Code, Dial Tone Detect, and Busy Tone Detect Configuration
Options.
Extended
Dial Tone
Busy Tone
Result Code:
Detect:
Detect:
X0
Disable
Disable
Disable
X1
Enable
Disable
Disable
X2
Enable
Enable
Disable
X3
Enable
Disable
Enable
X4
Enable
Enable
Enable
X5
Add/EC
Enable
Enable
X6
Add/V42.MNP
Enable
Enable
X7
Use DTE Rate
Enable
Enable
Extended Result
Code:
Configure\Edit\
DTE Dialer
Dial Tone Detect:
Configure\Edit\
Line Dialer
Busy Tone
Detect:
Configure\Edit\
Line Dialer
Extended Result Code:
Enable
Displays all result codes listed in Table 5-1 except for error
control suffix.
Disable
Only displays OK, CONNECT, RING, NO CARRIER,
ERROR
y
p y
,
,
,
,
ERROR.
Add/EC
Displays result codes with /EC suffix.
Add/V42,MNP
Displays result codes with V.42 or MNP suffix.
Use DTE Rate
Displays DTE data rate instead of line rate.
Dial Tone Detect:
Enable
Sets the modem for dial tone detect
Enable
Sets the modem for dial tone detect.
Disable
Sets the modem for blind dialing.
NOTE: It may not be possible to disable Dial Tone Detect in some countries.
Busy Tone Detect:
Enable
Modem monitors for busy tone.
Disable
Modem ignores busy tone.
Y
n
Long Space Disconnect.
Y0
Disable. Ignores long space.
Y1
Enable. Disconnects if long space is detected. Enables transmission
of a long space.
Configure/Edit/
Line Dialer
Z
n
Reset and Load Active.
Z0
Loads configuration options from Active (Saved) to Active
(Operating).
Z1
Loads configuration options from Customer 1 to Active (Operating).
Z2
Loads configuration from Customer 2 to Active (Operating).
Z3
Loads configuration options from Active (Saved) to Active
(Operating) and performs a reset.
Control\Reset