3920-A2-GN31-30

Table 5-2

(5 of 9)

392x

Plus AT Commands

AT

Command

DCP LCD

Command

Sequence

Description

&G

n

V.22bis Guard Tone.

&G0

Disable.

&G1

550 Hz.

&G2

1800 Hz.

Configure\Edit\
Dial Line

NOTE: The V.22bis Guard Tone cannot be disabled in some countries.

&

I

n

Dial Transmit Level.

The AT command is &

I

n, where n is

0 for – 0 dBm
1 for –1 dBm

32 for –32 dBm

Configure\Edit\
Dial Line

NOTE: In North America the range of allowable values is –10 dBm to –32 dBm.

This command is disabled in some countries (it answers OK but does not
change the level).

&L

n

Leased Mode.

&L0

Disables leased-line operation.

&L1

2-wire originate leased-line operation.

&L2

4-wire originate leased-line operation.

&L3

2-wire answer leased-line operation.

&L4

4-wire answer leased-line operation.

The &L command will cause the modem to reset before entering or exiting
Leased Line mode. Therefore, it must be entered as the last command in an
initialization string.

Configure\Edit\
Leased Line