Sample configuration — point-to-point msd, Point-to-point msd, Cables – Paradyne 392xPLUS User Manual
Page 267
COMSPHERE 392xPlus Modems
G-18
November 1996
3920-A2-GN31-30
Point-to-Point MSD
Figure G-9 shows a sample configuration for point-to-point MSD.
Figure G-9. Sample Configuration — Point-to-Point MSD
3920Plus A
Use Sync Lease Answer Template default configuration options with the
following exception:
Rate
Refer to the Sample Port Rate Table in this section.
3920Plus B
Use Sync Lease Originate Template default configuration options with the
following exception:
MSD Control
Set Ports 1, 2, and 3 to Enable.
Rate
Refer to the Sample Port Rate Table in this section.
Cables
Cable 1
Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug)
connector at one end to attach to the modem. Attach this to the connector labeled
DTE1, 2, 3, or 4.
Cable 2
Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is
supplied with the modem). Attach this to the connector labeled LEASED.
Cable 3
Use part number 818-2759-0111 or an equivalent customer-supplied,
EIA-232-D/V.24 crossover cable with DB-25-P (plug) connectors on both ends to
attach to the modems. (See Appendix C for pin assignments.)