Vf thresholds update – Paradyne 392xPLUS User Manual

Page 88

background image

DCP Operation

3-51

3920-A2-GN31-30

November 1996

VF Thresholds Update

The VF Thresholds Update function allows you to set the thresholds that determine the Health and
Status alarm conditions for the VF parameters. Refer to Table 3-8 in this section for VF

thresholds and their valid ranges and default values.

To access VF_Thresh_Update from the Control branch, make the following selections:

F1

Control:

<

VF_Thresh_Update

F2

F3

Press the

key until VF_Thresh_Update appears. Press any function key to select

VF_Thresh_Update.

F1

VF Thresholds
Edit Save Reset

F2

F3

Select Edit.

In the following example, the RSL High threshold is changed from 09 (–dBm) to 10. This example
demonstrates VF threshold editing and saving. With the exception of Signal Quality, all VF
thresholds may be modified in this manner. Signal Quality uses a menu selection with possible
values of Excelent (Excellent), Good, Fair, Poor, or No Signal. Editing and saving a VF threshold
is similar to editing and saving a configuration option. (For another example of editing and saving,
refer to the Editing and Saving a Configuration Option section in Chapter 4.)

F1

RSL High (- dBm)
Nxt

"

09

F2

F3

In the example shown above, 09 is the upper (High) RSL threshold (in –dBm). To change the
09 to 10, make the following selections:

F1

RSL High (- dBm)
Nxt

"

19

F2

F3

r

Select the F2 (

" ) key to increment the number above the cursor ( 0 ) to 1.