The following provides information about the Quick Configuration LCD display.

a

Displays the network position of the modem. The letter C indicates this is a
control modem, and T indicates this is a tributary modem.

bbb

Displays the network management address of the modem. The valid address field
range is from 001 to 256.

c

Displays the DTE mode. The letter A indicates the currently selected port is in
Asynchronous mode, and S indicates the currently selected port is in Synchronous
mode. If the NMS channel is selected, the letter in this location (A or S) will
indicate the status of Port 1. (The NMS channel is always in Asynchronous
mode.)

dd

Displays the line mode. The letters LA indicate Leased Answer mode, LO
indicate Leased Originate mode, and D indicates Dial mode.

ee

Displays the modem DTE port that currently appears by the EIA status indicators
on the DCP.

CC

indicates Control Channel.

DC

indicates Diagnostic Channel.

P1

indicates Port 1 in Singleport mode.

The following only appear on the 392x multiport modem:

M1

indicates Port 1 when TDM/MSD is enabled.

M2

indicates Port 2 when TDM/MSD is enabled.

M3

indicates Port 3 when TDM/MSD is enabled.

M4

indicates Port 4 when TDM/MSD is enabled.

B1

indicates Port 1 when DTE Bridge is enabled.

B2

indicates Port 2 when DTE Bridge is enabled.

ffff

Displays the modem’s modulation scheme as shown below:

V34

indicates V.34 family modulation.

V32t

indicates V.32 terbo modulation.

V32b

indicates V.32bis modulation.

V32

indicates V.32 modulation.

TMp

indicates Trellis Multipoint modulation.

V22b

indicates V.22bis modulation.

V27b

indicates V.27bis modulation.

V33

indicates V.33 modulation.

V29

indicates V.29 modulation.

V22

indicates V.22 modulation.

V23

indicates V.23 modulation.

V21

indicates V.21 modulation.

212A

indicates Bell 212A modulation.

103J

indicates Bell 103J modulation.

xxxx

Modem Transmit Rate indicates the rate at which the modem is transmitting data.
Possible values are 2400, 4800, 7200, 9600, 12.0 (12,000), 14.4 (14,400),
16.8 (16,800), 19.2 (19,200), 21.6 (21,600), 24.0 (24,000), 26.4 (26,400),
28.8 (28,800), 31.2 (31,200), or 33.6 (33,600) bps.

yyyyy

Symbol Rate indicates the baud rate used by V.34 modulation. Refer to CCITT
specifications. Possible values are 3429, 3200L, 3200H, 3000L, 3000H, 2800L,
2800H, 2743L, 2743H, 2400L, 2400H.

zz

Transmit Level indicates the power level at which the modem is transmitting
when running V.34 modulation. Possible values are 01– 64 dBm.

To exit the Quick Configuration function and return to the Top-Level menu, press the

,

,

or

key.