Chapter 3

Host Interface Menus

74

Idle Response

Values: Enable or Disable. The default value for this parameter is
Disable.

If you enable the Series 1 Idle parameter, then whenever the buffer
is less than 75% full, the printer sends a response character to the
host every two seconds.

NOTE: This parameter is used only with the SERIES 1, 1 CH and

SERIES 1, 2 CH protocols. For SERIES 1, 1 CH
information, see page 69. For SERIES 1, 2 CH information,
see page 70.

One Char Enquiry

The One Char Enquiry mode uses the Poll Character to detect a
request from the host and sends a response back to the host. This
option also allows you to turn this feature on and off. The default
setting is disabled.