[12] Memory Switch (continued)

11-44

The following functions can be provided by the Memory switch settings.

[1] Auto reset timer

Sets the time interval for the machine to reset to the initial condition.
Options: Off or 30/60/90/120/150/180/210/240/270/300 seconds.

[2] AUTO RESET effect

Sets the condition of Copy mode, Copy density, Magnification, and Paper tray
selection when the [AUTO RESET] key is pressed.
Options: Full-auto (factory setting) or Initial (key operator setting). Initial is the default
setting.

[3] Load RADF effect

Determines how the machine initializes when it is in the platen copy mode (non
RADF) and an original is inserted in the RADF feed tray.
Options: RADF and RADF + Auto Reset. The RADF option will activate the RADF
without resetting any other features. The RADF + Auto Reset option will activate the
RADF and reset the machine to the features programmed in memory switch #2.

[4] Non Image Area Erase

Establishes how the machine determines the image area of the copy.
Options: ON and APS/AMS only. ON option limits the copy image area to that of the
original. The APS/AMS only option limits the copy image area to that of the copy
paper sizes and the magnification automatically selected by the machine.

[5] RADF frame erasure

Sets the amount of frame erase when using the RADF.
Options: None, 1mm/ 2mm/ 3mm/ 4mm/ 5mm.

[6] Auto tray switch

During a copy job when ATS is on and multiple paper trays are loaded with the same
size paper, the machine will automatically switch to another tray when the initial tray
runs out of paper. Refer to memory switches 9 through 13 to activate this feature for
each tray.

[7] Platen APS

This feature allows the machine to automatically detect the size of the original placed
on the glass and select the same size copy paper. Refer to switches 9 through 13 to
activate this feature for each tray.

[8] RADF APS

This feature allows the machine to detect the size of the original fed through the
RADF. Refer to switches 9 through 13 to activate this feature for each tray.