Sanyo PLC-WXE46 User Manual
Page 9
PLC-WXE46/WXL46
Expand Serial Command Functional Specifications
9/65
3.
Notes for communication
1. Expand Serial Command is defined as one command / one line that starts with “C” and ends
with carriage return (0x0D)
2. There are two types of commands: Functional Execution Command and Status Read
Command.
- Example of Functional Execution Command:”CF_BRIGHT_032”[CR]
- Example of Status Read Command: “CR_RIGHT”[CR]
Note) ”_” means a space
3. When it takes more than one second to receive one command, it is not executed.
When it takes more than one second to receive carriage return (0X0D) after the projector
receives the first data “C”, it clears the information of buffer.
4. On command pipelining, wait for the interval of 100ms till sending next command after receiving
a response.
(More than 100ms)
Command
PC
→ Projector
“CF_BRIGHT_032” CR
Next Command
Projector
→ PC
“000” CR
Response
(A few ms - 5s)
When a computer sends next command before receiving a response, the projector may not operate
properly,except when there is no response for more than 5 seconds.
5. It takes about 5 seconds for internal initialization after plugging in AC power. During this time
commands cannot be processed. Do not issue any command.
4. Name Definition
1.
Data from a controller to a projector is represented as COMMAND, and data from a projector to
a controller for the incoming command is represented as RESPONSE.
2.
[CR] : Carriage Return Code
Command ends with cartridge return code.
Response also ends with carriage return code.
3.
_ : Space Code
A space Code is indicated by (_).
4.
%1 : Parameter in Command
When there are several parameters, they are defined as %2, %3…
5.
%%% : Error code returned from a projector
Acceptable: “000”.
Unacceptable: See [7. Error Code Table].
6.
%a : Parameter in Response Command
When there are several parameters, they are defined as %b, %c…