Sanyo PLC-WXE46 User Manual
Page 36

PLC-WXE46/WXL46
Expand Serial Command Functional Specifications
36/65
8.10.14 CF_RCODE Command
Command “CF_RCODE_%1”[CR]
%1
"001” --------------------------- Select Code1
"002” --------------------------- Select Code2
“UP” --------------- Switch Code setting of Remote Control forward
(Code1
→ Code2 → Code1
)
“DN” --------------- Switch Code setting of Remote Control backward
(Code2
→ Code1 → Code2
)
Details
Select Code of Remote Control
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]
8.10.15 CF_KEYDIS Command
Command “CF_KEYDIS_%1”[CR]
%1
“NONE” ----------------------- RC & Projector keys are valid (All are valid)
“RC” ---------------------------- RC keys are invalid
“KEY” -------------------------- Projector keys are invalid
Details
Diable RC/Projector keys
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]
8.10.16 CF_PJPINCODE Command
Command “CF_PJPINCODE_%1”[CR]
%1
“0000” – “9999” ---------Set PJ PIN CODE directly
Details
Set PJ PIN CODE to release PJ LOCK.
PIN CODE cannot be changed by this command.
-When PJ LOCK is in operation
PIN CODE is correct ------------------------- Command is valid (Acceptable)
PIN CODE is incorrect ----------------------- Command is invalid(Error Code”102”)
PIN CODE is out of %1 range ------------- Command is invalid (Error Code “? “)
-When PJ LOCK is not in operation
PIN CODE is within %1 range ---------------- Command is valid (Acceptable)
PIN CODE is out of %1 range ---------------- Command is invalid (Error Code “? “)
This command is valid during a dialog “PJ PIN CODE” is displayed after Power On
and Count down.
Also when PJ LOCK setting is “On1”, it is necessary to transmit this command
everytime lamp turns on.
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]