Sanyo PLC-WXE46 User Manual
Page 53
PLC-WXE46/WXL46
Expand Serial Command Functional Specifications
53/65
9.9 Lamp Status Read Command
9.9.1
CR_LAMPREPL Command
Command “CR_LAMPREPL”[CR]
Details
Get information of Lamp Replacement time
Response
Acceptable
“000_%1”[CR]
%1
“1Y” -------------------------- Over lamp replacement time
“1N” -------------------------- Within lamp replacement time
“1” means the number of lamps.
(1 lamp model
→ “1”)
“Y”/”N” means if it has reached its replacement time or not.
e.g. “1Y” -----------projector is 1 lamp model and Lamp is over its
replacement time
Unacceptable “Error Code”[CR]
9.9.2
CR_LAMPH Command
Command “CR_LAMPH”[CR]
Details
Get total running time of lamp by hour (h)
*Actual running time, not corresponding value
Response
Acceptable
“000_%1”[CR]
%1
“00000”~“99999”
Unacceptable “Error Code”[CR]
9.9.3
CR_LAMPCORRESPH Command
Command “CR_LAMPCORRESPH”[CR]
Details
Get total running time of lamp by hour (h)
* Corresponding value, not actual running time
Response
Acceptable
“000_%1”[CR]
%1
“00000”~“99999”
Unacceptable “Error Code”[CR]
9.9.4
CR_LAMPMODE Command
Command “CR_LAMPMODE”[CR]
Details
Get setting status of Lamp Mode
Response
Acceptable
“000_%1”[CR]
%1
“NORMAL” -------------- Lamp Mode is Normal
“ECO” --------------------- Lamp Mode is Eco
Unacceptable “Error Code”[CR]