9.7.5
CR_SRCINP3 Command
Command "CR_SRCINP3” [CR]
Details
Get selected source of Input 3_Video
Response
Acceptable
“000_%1”[CR]
Request data
“AUTO” -------------- Video Auto is selected
“VIDEO” ------------- Composite Video Input is selected
“S
VIDEO” -------- S-Video Input is selected
Unacceptable “Error Code”[CR]
9.7.6
CR_SYSTEM Command
Command “CR_SYSTEM”[CR]
Details
Get selected System
Response
Acceptable
“000_%1”[CR]
%1
Input is
PC Analog
“VGA1” -------------- VGA1 is selected
“VGA2” -------------- VGA2 is selected
“XGA1”-------------- XGA1 is selected
“WXGA3” --------- WXGA3 is selected
“1080i” ------------ 1080i is selected
“1035i” ------------ 1035i is selected
“720p” ------------- 720p is selected
“575p” ------------- 575p is selected
“480p” ------------- 480p is selected
“575i” -------------- 575i is selected
“480i” -------------- 480i is selected
“MODE1” ------- Mode1 is selected
“MODE5” -------------- Mode5 is selected
When there is no signal, projector returns error code”101”
[CR]
Input is
Y,Pb/Cb,Pr
/Cr
“AUTO” ----------- Auto is selected
“1080i” ------------1080i is selected
“1035i” ------------ 1035i is selected
“720p” ------------- 720p is selected
“575p” ------------- 575p is selected
“480p” ------------- 480p is selected
“575i” -------------- 575i is selected
“480i” -------------- 480i is selected
Projector returns selected System status regardless of the
signal input.
Input is
Video,S-Vi
deo
“AUTO” --------------- Auto is selected
“NTSC” --------------- NTSC is selected
“NTSC443” ---------- NTSC4.43 is selected
“PAL” ------------------ PAL is selected
“SECAM” ------------- SECAM is selected
“PAL
M” ------------- PAL-M is selected
“PAL
N” ------------- AL-N is selected
Projector returns selected System status regardless of the
signal input.
Unacceptable
““Error Code”[CR]