PLC-WXE46/WXL46
Expand Serial Command Functional Specifications
18/65
8.4.8
CF_COLTEMP Command
Command “CF_COLTEMP_%1”[CR]
%1
“000” ------ Xlow
“001” ------ Low
“002” ------ Mid
“003” ------ High
Details
Set Color Temperature. (Available only in the normal Power ON status)
The value set by this command will not be saved to the projector. Therefore, when
turning into Stanby-mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]
8.4.9
CF_PROGV Command
Command “CF_PROGV_%1”[CR]
%1
“FILM” -------- Select Progressive Mode FILM
“L1” ----------- Select Progressive Mode L1
“L2” ----------- Select Progressive Mode L2
“OFF” --------- Cancel Progressive scan
“UP” -----------Switch Progressive mode in positive order
OFF
→ L1 → L2 → FILM → OFF
“DN” -----------Switch Progressive mode in negative order
OFF
→ FILM → L2 → L1 → OFF
Details
Set / cancel Progressive scan
The value set by this command will not be saved to projector. Therefore, when
turning into Stanby-mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]
8.4.10 CF_NZRED Command
Command “CF_NZRED_%1”[CR]
%1
“OFF” ------- Cancel Noise Reduction
“L1” --------- Noise Reduction for moving image
“L2” --------- Noise Reduction for still image
“UP” -----------Switch Progressive mode in positive order
OFF
→ L1 → L2 → FILM → OFF
“DN” -----------Switch Progressive mode in negative order
OFF
→ FILM → L2 → L1 → OFF
Details
Noise Reduction based on frame correlation
Select L1 or L2 depending on motion detection
L2 is more effective in reducing noise than L1, however, L2 can have a blur in
moving image
The value set by this command will not be saved to projector. Therefore, when
turning into Stanby-mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]