beautypg.com

Sanyo PLC-WXE46 User Manual

Page 40

background image

PLC-WXE46/WXL46

Expand Serial Command Functional Specifications

40/65

8.11.4 CF_FREEZE Command

Command “CF_FREEZE_%1”[CR]

%1

“ON” ------------------------ Set Freeze to ON
“OFF” ----------------------- Set Freeze to OFF
“UP” ------------------------------ Switch setting (On

→ Off → On →

)

“DN” ------------------------------ Switch setting (On

→ Off → On →

)

Note) “UP” and “DN” behave the same.

Details

Set/Cancel Freeze setting.
Although projector returns “000”, receiving another Freeze command does not
release Freeze operation.
This command is available in normal Power ON status.

Response

Acceptable

“000”[CR]

Unacceptable “Error Code”[CR]

8.11.5 CF_VMUTE Command

Command “CF_VMUTE_%1”[CR]

%1

“ON” --------------------------- Set No show ON
“OFF” ------------------------- Set No show OFF
“UP” ------------------------------ Switch setting (On

→ Off → On →

)

“DN” ------------------------------ Switch setting (On

→ Off → On →

)

Note) “UP” and “DN” behave the same.

Details

Set/Cancel No show setting.
This command is available in normal Power ON status.

Response

Acceptable

“000”[CR]

Unacceptable “Error Code”[CR]

8.11.6 CF_PTIMER Command

Command “CF_PTIMER_%1”[CR]

%1

“SET” ---------------Excute P-TIMER

Details

Display / Suspend / Cancel P-TIMER
This command behaves the same as “P-TIMER” key of Remote Control /
Projector.

Response

Acceptable

“000”[CR]

Unacceptable “Error Code”[CR]