Sanyo PLC-WXE46 User Manual
Page 37

PLC-WXE46/WXL46
Expand Serial Command Functional Specifications
37/65
8.10.17 CF_FANMODE Command
Command “CF_FANMODE_%1”[CR]
%1
“L1” ---------------------------- Set Fan Mode to L1
“L2” ---------------------------- Set Fan Mode to L2
Details
Switch Fan Mode
When L1 is selected, fan noise after POWER OFF is louder.
When L2 is selected, fan noise after POWER OFF becomes quiet, however, fan
rotates longer than L1.
The status set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]
8.10.18 CF_FANCONTROL Command
Command “CF_FANCONTROL_%1”[CR]
%1
“OFF” ---------------------------- Set Fan control to Off
“ON1” ---------------------------- Set Fan control to On1
“ON2” ---------------------------- Set Fan control to On2
Details
Set Fan control setting.
The status set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]
8.10.19 CF_FILTIMER Command
Command “CF_FILTIMER_%1”[CR]
%1
“100” -------------------- Set 100 hours
“200” -------------------- Set 200 hours
“300” -------------------- Set 300 hours
“OFF” ------------------- No warning display
“UP” --------------------- Switch Filter timer in positive order
Off
→100 → 200 → 300 → Off
“DN” --------------------- Switch Filter timer in negative order
Off
→ 300 → 200 → 100
Details
Set timer of Filter warning display.
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]
8.10.20 CF_FILH Command
Command “CF_FILH_%1”[CR]
%1
“RST” ---------------Reset Filter used time
Details
Reset filter used time
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]