Table 6-12, Reference for decoding i, C diagnostic test messages – Sun Microsystems Sun Fire V490 User Manual
Page 139

Chapter 6
Diagnostic Tools
111
Reference for Decoding I
2
C Diagnostic
Test Messages
describes each I
2
C device in a Sun Fire V490 system, and helps you
associate each I
2
C address with the proper FRU. For more information about I
2
C
tests, see “I2C Bus Device Tests” on page 89.
except #,#
Tests all devices in the OpenBoot Diagnostics test menu except
those identified by the specified menu entry numbers
versions
Displays the version, last modified date, and manufacturer of
each self-test in the OpenBoot Diagnostics test menu and
library
what #,#
Displays selected properties of the devices identified by menu
entry numbers. The information provided varies according to
device type
TABLE 6-12
Sun Fire V490 I
2
C Bus Devices
Address
Associated FRU
What the Device Does
fru@0,a0
processor 0, DIMM 0
Provides configuration
information for processor 0 DIMMs
fru@0,a2
processor 0, DIMM 1
fru@0,a4
processor 0, DIMM 2
fru@0,a6
processor 0, DIMM 3
fru@0,a8
processor 0, DIMM 4
fru@0,aa
processor 0, DIMM 5
fru@0,ac
processor 0, DIMM 6
fru@0,ae
processor 0, DIMM 7
TABLE 6-11
OpenBoot Diagnostics Test Menu Commands (Continued)
Command
Description