Prtfru command – Sun Microsystems Sun Fire V490 User Manual
Page 124

96
Sun Fire V490 Server Administration Guide • August 2004
In addition to that information, prtdiag with the verbose option (-v) also reports
on front panel status, disk status, fan status, power supplies, hardware revisions,
and system temperatures.
CODE EXAMPLE 6-9
prtdiag
Verbose Output
In the event of an overtemperature condition, prtdiag reports an error in the Status
column.
CODE EXAMPLE 6-10
prtdiag
Overtemperature Indication Output
Similarly, if there is a failure of a particular component, prtdiag reports a fault in
the appropriate Status column.
CODE EXAMPLE 6-11
prtdiag
Fault Indication Output
prtfru
Command
The Sun Fire V490 system maintains a hierarchical list of all field-replaceable units
(FRUs) in the system, as well as specific information about various FRUs.
System Temperatures (Celsius):
-------------------------------
Device
Temperature
Status
---------------------------------------
CPU0 59 OK
CPU2 64 OK
DBP0 22 OK
System Temperatures (Celsius):
-------------------------------
Device
Temperature
Status
---------------------------------------
CPU0
62
OK
CPU1
102
ERROR
Fan Status:
-----------
Bank RPM Status
---- ----- ------
CPU0 4166 [NO_FAULT]
CPU1 0000 [FAULT]