10/100base-tx pin assignments – SMC Networks ElliteConnect 2.4GHz/5GHz User Manual
Page 306
Cables and Pinouts
C-2
10/100BASE-TX Pin Assignments
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP)
cable for RJ-45 connections: 100-ohm Category 3 or better cable
for 10 Mbps connections, or 100-ohm Category 5 or better cable
for 100 Mbps connections. Also be sure that the length of any
twisted-pair connection does not exceed 100 meters (328 feet).
The RJ-45 Input port on the power injector is wired with MDI
pinouts. This means that you must use crossover cables for
connections to PCs or servers, and straight-through cable for
connections to switches or hubs. However, when connecting to
devices that support automatic MDI/MDI-X pinout configuration,
you can use either straight-through or crossover cable.
10/100BASE-TX MDI and MDI-X Port Pinouts
Pin
MDI-X Signal Name
MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)
4,5,7,8
Not used
Not used
Note: The “+” and “-” signs represent the polarity of the wires that
make up each wire pair.