X6DH3-G2/X6DHi-G2 User's Manual

4. The ACU allows you to use drives of different sizes in a RAID . However, during a

build operation, only the smaller drive can be selected as the source or fi rst drive.

5. When migrating from single volume to RAID 0, migrating from a larger drive to

a smaller drive is allowed. However, the destination drive must be at least half the

capacity of the source drive.

6. Adaptec does not recommend that you migrate or build an array on Windows

dynamic disks (volumes), as it will result in data loss.

Warning: Do not interrupt the creation of a RAID 0 using the Migrate option. If you do,

you will not be able to restart, or to recover the data that was on the source drive.

Adding a Bootable Array

To make an array bootable:

1. From the Main menu, select Manage Arrays.

2. From the List of Arrays, select the array you want to make bootable, and press

Ctrl+B.

3. Enter Y to create a bootable array when the following message is displayed: "This

will make all other existing bootable array non-bootable. Do you want to make this

array bootable? (Yes/No):" Then, a bootable array will be created. An asterisk will

appear next to the bootable array.

Deleting a Bootable Array

To delete a bootable array:

1. From the Main menu, select Manage Arrays.

2. From the List of Arrays, select the bootable array (*) you want to delete, and press

Ctrl+B. (* a bootable array is the array marked with an asterisk.)

3. Enter Y to delete a bootable array when the following message is displayed: "The

array is already marked bootable. Do you want to make this array as not bootable?

(Yes/No):" Then, the bootable array will be deleted and the asterisk will disap-

pear.

(Note: do not use the delete key to delete the bootable array.)